{"id":42,"date":"2024-04-03T23:09:24","date_gmt":"2024-04-03T20:09:24","guid":{"rendered":"https:\/\/sisu.ut.ee\/measurement\/10-approach-based-validation-and-quality-control-data-top-down-approach\/"},"modified":"2024-06-19T16:39:20","modified_gmt":"2024-06-19T13:39:20","slug":"10-approach-based-validation-and-quality-control-data-top-down-approach","status":"publish","type":"page","link":"https:\/\/sisu.ut.ee\/measurement\/10-approach-based-validation-and-quality-control-data-top-down-approach\/","title":{"rendered":"10. Approach based on validation and quality control data (also known as the single-lab validation approach)"},"content":{"rendered":"<p><strong>Brief summary:\u00a0<\/strong>This section explains the so-called single-lab validation approach. We will look at the formalization of this approach published by Nordtest.\u00a0<a href=\"#\" data-bs-toggle=\"modal\" data-bs-target=\"#popup-modal\" data-title=\"[1]\" data-content='&lt;em&gt;Handbook for Calculation of Measurement Uncertainty in Environmental Laboratories&lt;\/em&gt;. B. Magnusson, T. N\u00e4ykki, H. Hovind, M. Krysell, E. Sahlin. Nordtest technical report 537, ed. 4.0. Nordtest,\u00a0&lt;strong&gt;2017&lt;\/strong&gt;. Available on-line from\u00a0&lt;a title=\"\" href=\"http:\/\/www.nordtest.info\/wp\/2017\/11\/29\/handbook-for-calculation-of-measurement-uncertainty-in-environmental-laboratories-nt-tr-537-edition-4\/\" target=\"_blank\" rel=\"noopener\" data-url=\"http:\/\/www.nordtest.info\/wp\/2017\/11\/29\/handbook-for-calculation-of-measurement-uncertainty-in-environmental-laboratories-nt-tr-537-edition-4\/\"&gt;http:\/\/www.nordtest.info\/wp\/2017\/11\/29\/handbook-for-calculation-of-measurement-uncertainty-in-environmental-laboratories-nt-tr-537-edition-4\/&lt;\/a&gt;\u00a0'>[1]<\/a>Therefore in this course this approach is often called \u201cthe Nordtest approach\u201d. The single-lab validation approach, contrary to the ISO GUM modeling approach, does not go deeply into the measurement procedure and does not attempt to quantify all uncertainty sources individually. Instead uncertainty sources are quantified in large \u201cbatches\u201d via components that take a number of uncertainty sources into account. Most of the data that are used come from validation of the analytical procedure. This is the reason for the word \u201cvalidation\u201d in the name of the approach. This type of approach is also sometimes called the \u201ctop-down\u201d approach.<\/p>\n<p>Sections 10.1 to 10.3 present the Nordtest approach step by step and explain the way of obtaining necessary data. Section 10.4 gives a \u201croadmap\u201d of the Nordtest approach. Section 10.5 presents a practical example of applying the Nordtest approach in the case of determination of acrylamide in snacks by liquid chromatography mass spectrometry (LC-MS).<\/p>\n<ul class=\"menu clearfix\">\n<li><a style=\"line-height: 1.6em;\" title=\"\" href=\"https:\/\/sisu.ut.ee\/measurement\/101-principle-absolute-and-relative-quantities\/\">10.1. Principles<\/a><\/li>\n<li><a style=\"line-height: 1.6em;\" title=\"\" href=\"https:\/\/sisu.ut.ee\/measurement\/102-estimating-uncertainty-component-accounting-random-effects-using-data-are-available\/\">10.2. Uncertainty component accounting for random effects<\/a><\/li>\n<li><a title=\"\" href=\"https:\/\/sisu.ut.ee\/measurement\/103-estimating-uncertainty-component-accounting-systematic-effects-using-data-are\/\">10.3. Uncertainty component accounting for systematic effects<\/a><\/li>\n<li><a title=\"\" href=\"https:\/\/sisu.ut.ee\/measurement\/104-practical-example\/\">10.4. Roadmap<\/a><\/li>\n<li><a style=\"line-height: 1.6em;\" title=\"\" href=\"https:\/\/sisu.ut.ee\/measurement\/105-practical-example-uncertainty-estimation-using-nordtest-approach\/\">10.5. Determination of acrylamide in snacks by LC-MS<\/a><\/li>\n<\/ul>\n<p><span style=\"line-height: 1.6em;\">***<\/span><\/p>\n<p><span style=\"line-height: 1.6em;\">[1]\u00a0<\/span><em>Handbook for Calculation of Measurement Uncertainty in Environmental Laboratories<\/em>. B. Magnusson, T. N\u00e4ykki, H. Hovind, M. Krysell, E. Sahlin. Nordtest technical report 537, ed. 4.0. Nordtest,\u00a0<strong>2017<\/strong>. Available on-line from\u00a0<a title=\"\" href=\"http:\/\/www.nordtest.info\/wp\/2017\/11\/29\/handbook-for-calculation-of-measurement-uncertainty-in-environmental-laboratories-nt-tr-537-edition-4\/\" target=\"_blank\" rel=\"noopener\">http:\/\/www.nordtest.info\/wp\/2017\/11\/29\/handbook-for-calculation-of-measurement-uncertainty-in-environmental-laboratories-nt-tr-537-edition-4\/<\/a><\/p>\n<p><span style=\"line-height: 1.6em;\">***<\/span><\/p>\n<p><span style=\"line-height: 1.6em;\">The slides presented in this section are available from<\/span> here:\u00a0<\/p>\n<p>\u00a0<\/p>\n\n\n<div class=\"wp-block-group attached-files-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-file\"><a id=\"wp-block-file--media-3b9be0a1-b7ea-4a7c-8294-da7127795c94\" href=\"https:\/\/sisu.ut.ee\/wp-content\/uploads\/sites\/18\/single-lab_validation_nordtest_uncertainty.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">single-lab_validation_nordtest_uncertainty.pdf<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Brief summary:\u00a0This section explains the so-called single-lab validation approach. We will look at the formalization of this approach published by Nordtest.\u00a0Therefore in this course this approach is often called \u201cthe Nordtest approach\u201d. The single-lab validation approach, contrary to the ISO &#8230;<\/p>\n","protected":false},"author":14,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-42","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/pages\/42","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/users\/14"}],"replies":[{"embeddable":true,"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/comments?post=42"}],"version-history":[{"count":3,"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/pages\/42\/revisions"}],"predecessor-version":[{"id":696,"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/pages\/42\/revisions\/696"}],"wp:attachment":[{"href":"https:\/\/sisu.ut.ee\/measurement\/wp-json\/wp\/v2\/media?parent=42"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}